Aller au contenu principal
Undrained seismic response of underground structures

Undrained seismic response of underground structures

Par Sandoval, Eimar Andrés

Publié par Universidad del Valle

Spanish 262 pages 2020 ISBN 9789585144545
Temps de lecture estimé : 4 h 48 min
PDF

À propos de ce livre

Underground structures must be able to support static overburden loads, as well as to accommodate additional deformations imposed by seismic motions. It seems well established that the most critical demand to the structure is caused by shear waves traveling perpendicular to the tunnel axis, which cause distortions of the cross section (ovaling for a circular tunnel, and racking for a rectangular tunnel) that result in axial forces (thrusts) and bending moments. While all this has been well-studied for structures placed in linear-elastic ground under drained loading conditions, there is little information regarding the behavior of buried structures placed in nonlinear ground, especially under undrained loading conditions, i.e., when excess pore pressures generate and accumulate during the earthquake. This book includes results of two-dimensional dynamic numerical analyses conducted to assess the seismic response of deep circular tunnels located far from the seismic source, under drained or undrained loading conditions. It is assumed that the liner remains elastic and that plane strain conditions apply. A new cyclic elastoplastic constitutive model is proposed to predict the nonlinear behavior and the excess pore pressures in the ground. The effect of the input frequency on the tunnel distortions of the cross section, and the effect of the relative stiffness between the liner and the ground on the distortions of the cross section, as well as, on the axial forces and bending moments of the liner are investigated. Excess pore pressures, shear stresses and plastic strains in the ground for different relative stiffness are also investigated.

Disponibilité

Undrained seismic response of underground structures est disponible en PDF dans 22 librairies en ligne. Parmi les librairies qui le proposent : Alpha Books, Bajalibros Argentina, Bajalibros Colombia.

Langue
Spanish
Partager

Questions fréquentes

Dans quels formats Undrained seismic response of underground structures est-il disponible ?
Undrained seismic response of underground structures est disponible en PDF dans 22 librairies en ligne.
Où puis-je acheter Undrained seismic response of underground structures ?
Vous pouvez acheter Undrained seismic response of underground structures sur Alpha Books, Bajalibros Argentina, Bajalibros Colombia. Comparez toutes les options dans la liste de cette page.
Combien de temps faut-il pour lire Undrained seismic response of underground structures ?
À un rythme de lecture moyen, Undrained seismic response of underground structures se lit en environ 4 h 48 min (262 pages).

Notes et avis

Pas encore de note. Soyez le premier à donner votre avis sur ce livre.

Se connecter pour noter ce livre et donner votre avis.

Commentaires

Se connecter pour rejoindre la conversation.

Pas encore de commentaires.